Built
in aluminium and stainless steel to avoid corrosion due to the presence of
ozone inside the discharge station.
High mechanical and electrical strenght of H.V. Insulators.
The stainless steel discharge electrodes are free to rotate in the
direction of the film (allowing for passage of joints or edge trims).
Precise AIR GAP regulation along the entire lenght of the electrode:
Insulated coating on discharge roller in vulcanised silicone rubber (other
coatings can be supplied on request)
Pneumatically-operated opening of the electrode housing hood to facilitate
passage of film.
Pressure roller for elimination of treatment crossover.
SAFETY DEVICES:
Discharge
roller rotation sensor
Proximity switch for station closed position
Pneumatically-operated safety interlock to prevent accidental clousure
Static and dinamic balance of rollers
Built in conformance with CE regulations
|